KZPSA PCI-to-SCSI
Storage Adapter
User's Guide
Order Number: EK–KZPSA–UG. B01
Digital Equipment Corporation
Maynard, Massachusetts
Vue de la page 0
1 2 3 4 5 6 ... 66 67

Résumé du contenu

Page 1 - Storage Adapter

KZPSA PCI-to-SCSIStorage AdapterUser's GuideOrder Number: EK–KZPSA–UG. B01Digital Equipment CorporationMaynard, Massachusetts

Page 2

EK–KZPSA–UG. B01 1–11Product DescriptionThis chapter provides a product description of the KZPSA PCI-to-SCSI Storage Adapter. It alsolists the operat

Page 3 - Contents

KZPSA PCI-to-SCSI Storage Adapter1–2 EK–KZPSA–UG. B01The adapter’s processor minimizes the SCSI I/O overhead of the host computer’sprocessor by interp

Page 4

Chapter 1. Product DescriptionEK–KZPSA–UG. B01 1–3PCI Bus Interface• Up to 133 MB/sec data transfer rate on the PCI bus• PCI single and dual address

Page 5 - EK–KZPSA–UG. B01 v

KZPSA PCI-to-SCSI Storage Adapter1–4 EK–KZPSA–UG. B011.2 StandardsThe KZPSA adapter conforms to the Standards listed in Table 1–1.Table 1–1 Standards

Page 6 - Revision Record

EK–KZPSA–UG. B01 2–12Configuration GuidelinesBefore you install the KZPSA PCI-to-SCSI storage adapter in your computer, you need to be-come familiar w

Page 7 - About This Guide

KZPSA PCI-to-SCSI Storage Adapter2–2 EK–KZPSA–UG. B01These defaults were chosen for optimum performance of the adapter. If they areacceptable for your

Page 8

Chapter 2. Configuration GuidelinesEK–KZPSA–UG. B01 2–32.4 SCSI Bus TerminationBus termination is required at each end of the SCSI bus. Typically, the

Page 9 - Conventions

KZPSA PCI-to-SCSI Storage Adapter2–4 EK–KZPSA–UG. B012.5 SCSI Termination PowerIt is normal for adapters, not devices, to supply termination power to

Page 10 - Product Description

Chapter 2. Configuration GuidelinesEK–KZPSA–UG. B01 2–52.11 Device DisconnectsTo optimize overall SCSI bus performance, the adapter default allows dev

Page 11 - 1–2 EK–KZPSA–UG. B01

EK–KZPSA–UG. B01 3–13Installing the KZPSA AdapterThis chapter describes how to install the KZPSA adapter board into a computer.3.1 UnpackingUnpack the

Page 12 - EK–KZPSA–UG. B01 1–3

Second Printing, April 1995While Digital believes the information included in this publication is correct as of thedate of publication, it is subject

Page 13 - 1.3 Specifications

KZPSA PCI-to-SCSI Storage Adapter3–2 EK–KZPSA–UG. B013.2 Hardware Installation ProcedureCAUTIONStatic electricity can destroy the circuits on theKZPSA

Page 14 - Configuration Guidelines

Chapter 3. Installing the KZPSA AdapterEK–KZPSA–UG. B01 3–3Figure 3–1 Typical KZPSA InstallationsWith factory-installed metal extender guide.With alt

Page 15 - 2.2 PCI Bus Configuration

KZPSA PCI-to-SCSI Storage Adapter3–4 EK–KZPSA–UG. B01Figure 3–1 Typical KZPSA Installations (continued)With alternate plastic extender guide.

Page 16 - 2.4 SCSI Bus Termination

Chapter 3. Installing the KZPSA AdapterEK–KZPSA–UG. B01 3–5Figure 3–2 Connecting SCSI Cable

Page 17 - 2–4 EK–KZPSA–UG. B01

EK–KZPSA–UG. B01 4–14OpenVMS AXP and OSF/1 SystemsThis chapter provides information which is unique to the installation and use of your KZPSAadapter

Page 18 - 2.11 Device Disconnects

KZPSA PCI-to-SCSI Storage Adapter4–2 EK–KZPSA–UG. B01If there is an error, try system power-on again. If the KZPSA error persists, referto Chapter 7,

Page 19 - Installing the KZPSA Adapter

Chapter 4. OpenVMS AXP and OSF/1 SystemsEK–KZPSA–UG. B01 4–34.4 KZPSA SCSI IDThe SCSI ID of the KZPSA adapter is set by default to 7. If you want to c

Page 20 - 3–2 EK–KZPSA–UG. B01

KZPSA PCI-to-SCSI Storage Adapter4–4 EK–KZPSA–UG. B014.7 KZPSA Device BootingThe SRM console can be used to set a default device, such as a device on

Page 21 - EK–KZPSA–UG. B01 3–3

EK–KZPSA–UG. B01 5–15Windows NT AXP SystemsThis chapter provides information which is unique to the installation and use of your KZPSAadapter with th

Page 22 - 3–4 EK–KZPSA–UG. B01

KZPSA PCI-to-SCSI Storage Adapter5–2 EK–KZPSA–UG. B012. Power up your system; the Alpha AXP should go through its start up se-quence and then display

Page 23 - EK–KZPSA–UG. B01 3–5

EK–KZPSA–UG. B01 iiiContents1 Product Description1.1 Introduction...

Page 24 - OpenVMS AXP and OSF/1 Systems

Chapter 5. Windows NT AXP SystemsEK–KZPSA–UG. B01 5–36. Note that the third line in the list contains a Vendor Id field of “1011” and adevice type of

Page 25 - 4–2 EK–KZPSA–UG. B01

KZPSA PCI-to-SCSI Storage Adapter5–4 EK–KZPSA–UG. B018. Insert the diskette labeled KZPSA Alpha AXP Software into the floppy drive. The prompt “a:\” i

Page 26 - 4.6 SCSI Fast Data Transfer

EK–KZPSA–UG. B01 6–16KZPSA Adapter UtilitiesThis chapter describes the KZPSA Adapter Utilities. It describes how to run the Configurationand Diagnosti

Page 27 - 4.7 KZPSA Device Booting

KZPSA PCI-to-SCSI Storage Adapter6–2 EK–KZPSA–UG. B01NOTERefer to the Release Notes for the minimum revi-sion levels of the ARC firmware.Select Run a

Page 28 - Windows NT AXP Systems

Chapter 6. KZPSA Adapter UtilitiesEK–KZPSA–UG. B01 6–3 • Device specific parameters: – Wide negotiation – Synchronous negotiation – Tagged queuing

Page 29 - 5–2 EK–KZPSA–UG. B01

KZPSA PCI-to-SCSI Storage Adapter6–4 EK–KZPSA–UG. B01Figure 6–1 Initial ScreenUse the arrow keys to select the KZPSA you wish to configure or test. O

Page 30 - EK–KZPSA–UG. B01 5–3

Chapter 6. KZPSA Adapter UtilitiesEK–KZPSA–UG. B01 6–5Figure 6–2 OptionsUse the arrow keys to select the option you wish to proceed with. You can sel

Page 31 - 5–4 EK–KZPSA–UG. B01

KZPSA PCI-to-SCSI Storage Adapter6–6 EK–KZPSA–UG. B01Figure 6–3 SCSI OptionsUse the arrow keys to select the following:• List existing SCSI devices•

Page 32 - KZPSA Adapter Utilities

Chapter 6. KZPSA Adapter UtilitiesEK–KZPSA–UG. B01 6–7Figure 6–4 Configuring Device Specific ParametersUse the arrow keys to move through the device

Page 33 - Key Function

KZPSA PCI-to-SCSI Storage Adapter6–8 EK–KZPSA–UG. B01Figure 6–5 DiagnosticsThe user can run the Power-On Self Test (POST) or SCSI Device Self Tests.U

Page 34 - EK–KZPSA–UG. B01 6–3

KZPSA PCI-to-SCSI Storage Adapteriv EK–KZPSA–UG. B015 Windows NT AXP Systems5.1 Software Supplied...

Page 35 - Figure 6–1 Initial Screen

Chapter 6. KZPSA Adapter UtilitiesEK–KZPSA–UG. B01 6–9Figure 6–6 Error Log Example

Page 36 - Figure 6–2 Options

KZPSA PCI-to-SCSI Storage Adapter6–10 EK–KZPSA–UG. B016.3 Firmware Update UtilityNOTEThe KZPSA firmware requires approximately oneminute to load in th

Page 37 - Figure 6–3 SCSI Options

Chapter 6. KZPSA Adapter UtilitiesEK–KZPSA–UG. B01 6–11Figure 6–8 Firmware Update UtilityPressing Enter initiates the firmware update process. Pressi

Page 38 - EK–KZPSA–UG. B01 6–7

EK–KZPSA–UG. B01 7–17TroubleshootingThis chapter provides troubleshooting information to help diagnose problems that can occur dur-ing the installatio

Page 39 - Figure 6–5 Diagnostics

KZPSA PCI-to-SCSI Host Adapter7–2 EK–KZPSA–UG. B017.2 System Power-on ProblemsAfter you turn on your host system, the CPU either performs a series of

Page 40 - Figure 6–6 Error Log Example

Chapter 7. TroubleshootingEK–KZPSA–UG. B01 7–37.3 SCSI Device ProblemsTable 7–2 lists a SCSI device problem, specifies the probable causes, and sug-ge

Page 41 - 6.3 Firmware Update Utility

KZPSA PCI-to-SCSI Host Adapter7–4 EK–KZPSA–UG. B01Table 7–2 SCSI Device Troubleshooting Table (Continued)Symptom Probable Cause Corrective ActionSCSI

Page 42 - EK–KZPSA–UG. B01 6–11

Chapter 7. TroubleshootingEK–KZPSA–UG. B01 7–57.4 Boot Sequence ProblemsTable 7–3 describes possible problems during the boot sequence, specifies thei

Page 43 - Troubleshooting

Copyright © Digital Equipment Corporation EK-KZPSA-RN. A011995 All Rights Reserved Page 1Release NotesKZPSA SCSI Storage Adapter ModuleBe sure to read

Page 44 - 7.2 System Power-on Problems

StorageWorks KZPSA SCSI Storage AdapterPage 2 EK-KZPSA-RN. A01Verified Device ListingDevice Type Note FW REV OSF/1 Windows NT8-bit Single-Ended Device

Page 45 - 7.3 SCSI Device Problems

ContentsEK–KZPSA–UG. B01 vFigures1–1 KZPSA PCI-to-SCSI Storage Adapter... 1–12–1 KZPSA Terminatio

Page 46 - Continued)

Release NotesEK-KZPSA-RN. A01 Page 3Mandatory Console Code UpdateDuring the qualification testing of the KZPSA, some critical problems were found with

Page 47 - 7.4 Boot Sequence Problems

StorageWorks KZPSA SCSI Storage AdapterPage 4 EK-KZPSA-RN. A012. Answer "yes" to the question to confirm update inquiry. Confirm update on

Page 48 - Release Notes

EK–KZPSA–UG. B01 A–1AAdditional InformationThis appendix provides the part number of some of the additional items you may need when youinstall the KZP

Page 49 - Verified Device Listing

EK–KZPSA–UG. B01 B–1BSample KZPSA Adapter ConfigurationsThis appendix describes three possible configurations in which differential and single-endedS

Page 50 - Mandatory Console Code Update

KZPSA PCI-to-SCSI Storage AdapterB–2 EK–KZPSA–UG. B01B.2 Bus Converter Configuration (8-Bit Single-Ended)Figure B–1 shows a KZPSA adapter configured t

Page 51 - Restrictions

Appendix B. Sample KZPSA ConfigurationsEK–KZPSA–UG. B01 B–3Figure B–1 Bus Converter ConfigurationSYSTEMMODULEPCI BusKZPSAADAPTERHOSTSYSTEMSYSTEMMODUL

Page 52 - Additional Information

KZPSA PCI-to-SCSI Storage AdapterB–4 EK–KZPSA–UG. B01NOTERefer to your StorageWorks Array Controllersdocuments for specific information on how to con-

Page 53 - B.1 Configuration Summary

Appendix B. Sample KZPSA ConfigurationsEK–KZPSA–UG. B01 B–5Figure B–2 RAID Subsystem ConfigurationSYSTEMMODULEPCI BusKZPSAADAPTERHOSTSYSTEMSYSTEMMODU

Page 54 - B.2.3 SCSI Bus Termination

KZPSA PCI-to-SCSI Storage AdapterB–6 EK–KZPSA–UG. B01B.4 DECsafe Available Server Environment (ASE) ConfigurationA DECsafe Available Server Environmen

Page 55 - EK–KZPSA–UG. B01 B–3

Appendix B. Sample KZPSA ConfigurationsEK–KZPSA–UG. B01 B–7Figure B–3 DECsafe Available Server Environment (ASE) ConfigurationSYSTEMMODULEPCI BusKZPS

Page 56 - B.3.3 SCSI Bus Termination

EK–KZPSA–UG. B01 viiRevision RecordThis Revision Record provides a concise publication history of this guide. It lists the guiderevision levels, rele

Page 57 - EK–KZPSA–UG. B01 B–5

KZPSA PCI-to-SCSI Storage AdapterB–8 EK–KZPSA–UG. B01B.4.2 SCSI ID SelectionOne KZPSA adapter is assigned SCSI ID 7 and the other KZPSA adapter is as

Page 58 - B–6 EK–KZPSA–UG. B01

EK–KZPSA–UG. B01 G–1GlossaryadapterA device that converts the protocol and hardware interface of one bus type intothat of another without changing the

Page 59 - EK–KZPSA–UG. B01 B–7

KZPSA PCI-to-SCSI Storage AdapterG–2 EK–KZPSA–UG. B01differential SCSI busA signal path where the signal's level is determined by the potential d

Page 60 - B.4.3 SCSI Bus Termination

GlossaryEK–KZPSA–UG. B01 G–3portSocket on the front or back of the system unit to which a terminal, printer, mo-dem or other device is connected.RAIDR

Page 61 - Glossary

KZPSA PCI-to-SCSI Storage AdapterG–4 EK–KZPSA–UG. B01SCSI jumpersRemovable electrical connectors on some drives that determine the SCSI addresssetting

Page 62 - G–2 EK–KZPSA–UG. B01

GlossaryEK–KZPSA–UG. B01 G–5terminatorResistor array device used for terminating a SCSI bus. A SCSI bus must be ter-minated at its two physical ends.

Page 63 - EK–KZPSA–UG. B01 G–3

Reader’s CommentsManual Order Number:EK–KZPSA–UG. B01Digital is committed to providing the best products and services. Since our manuals areimportant

Page 65 - EK–KZPSA–UG. B01 G–5

EK–KZPSA–UG. B01 ixAbout This GuideThis section identifies the audience of this guide and describes the contents (chapter-by-chapter) and structure. I

Page 66 - Reader’s Comments

KZPSA PCI-to-SCSI Storage Adapterx EK–KZPSA–UG. B01Chapter 3: Installing the KZPSA AdapterInstalling the KZPSA PCI-to-SCSI Storage Adapter describes

Page 67

About This GuideEK–KZPSA–UG. B01 xiAppendix B: Sample KZPSA Adapter ConfigurationsSample KZPSA Adapter Configurations describes three possibleconfigu