Seagate ST3250824NS Guide de dépannage Page 12

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 32
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 11
12 R/Evolution 2730 Release Notes for Software Version J200R05 October 2007
Updating the Controllers Using RAIDar
Caution – Do not attempt to upgrade both controllers at the same time. It is not
supported and will result in unpredictable failures and may yield unpredictable
results.
Note – Enable pop-ups on your browser for each controller. The upgrade process
will produce a pop-up window to show you the progress of downloading the code.
1. Stop all host I/O.
2. Log in to RAIDar on controller A as a Manage user with the correct password.
3. Disable the Partner Firmware Upgrade (PFU) feature.
a. Select Manage > General Config > System Configuration.
b. Set Partner Firmware Upgrade to Disabled.
c. Click Change System Configuration.
When processing is complete, a message near the top of the page informs you
that your change was successful.
4. Select Manage > Update Software > Controller Software.
5. Click Browse and locate
neptunesw-J200R05-01.bin.
6. Click Load Software Package File.
When processing is complete, the page shows the version of each software
component that will be installed.
7. Click on Proceed With Code Update.
The update may take up to 10 minutes to complete.
To see the progress of the code load, refresh your browser frequently.
When you see the message “Storage Controller and Management Controller will
reboot in 60 seconds,” the code load has completed. However, the controllers will
not reboot.
Note – When the update is complete, controller B will kill controller A. This is
normal. The firmware versions between the two controllers are not compatible.