Seagate ST3400071FC Guide de l'utilisateur Page 684

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 718
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 683
28.16
Command Line Interface Reference InForm OS Version 2.2.4
RESTRICTIONS
Use of this command requires a Dynamic Optimization license. Contact your local 3PAR
representative for information.
This command requires sufficient available physical space with the same owner or backup
node as the space it is being copied from.
EXAMPLES
The following example shows how to use the tunetpvv command to change the RAID type of
a thin provisioned virtual volume (
testvol) from cpg1, which is originally cpg1, which is of
RAID 1.
The following example shows how to use the tunetpvv command to increase the availability
level of a thin provisioned virtual volume (
testvol). Note that there is mag availability
because
testvol was originally on cpg1, which is created with option (–ha mag). To increase
cage availability, create a common provisioning group with cage availability and tune
testvol
to the associated CPG.
The following example shows how to tune multiple virtual volumes together.
Testvol.0,
testvol.1 and testvol.2 are the three virtual volumes to be tuned:
cli% createcpg –t r5 cpg2
cli% tunetpvv –cpg cpg2 testvol
Are you sure you want to tune VV 'testvol' ?
select y=yes n=no: y
Task 1 started.
cli% createcpg cpg3
cli% tunetpvv –cpg cpg3 testvol
Are you sure you want to tune VV ‘testvol’?
select y=yes n=no: y
Task2 started.
cli% tunetpvv –cnt 3 testvol
Are you sure you want to tune VV ‘testvol’?
select y=yes n=no: y
Task 3 started.
Vue de la page 683
1 2 ... 679 680 681 682 683 684 685 686 687 688 689 ... 717 718

Commentaires sur ces manuels

Pas de commentaire