30.4
Command Line Interface Reference InForm OS Version 2.2.4
COMMAND
upgradepd
DESCRIPTION
The upgradepd command upgrades the physical disk firmware.
SYNTAX
upgradepd [-f] [-skiptest] {-a | -w <WWN>... | <pdid>...}
AUTHORITY
Service
OPTIONS
–f
Upgrades the physical disk firmware without requiring confirmation.
–skiptest
Skips the 10 second diagnostic test normally completed after each physical disk upgrade.
–a
Specifies that all physical disks that have valid IDs and whose firmware is not current are
upgraded. If this option is not specified, then either the
–w option or PD_ID specifier must
be issued on the command line.
–w <WWN>...
Specifies that the firmware of either one or more physical disks, identified by their WWNs,
is upgraded. If this option is not specified, then either the
–a option or PD_ID specifier
must be issued on the command line.
SPECIFIERS
<PD_ID>...
Specifies that the firmware of either one or more physical disks identified by their IDs
(
PD_ID) is upgraded. If this specifier is not used, then the –a option or –w option must be
issued on the command line.
NOTE: You need access to all domains in order to run this command.