Release Notes 25
2090 After pulling the SAS expander
cable from Controller B on the 36
drive configuration, two Vdisks
went offline
2152 VSS error (delete all leaves 2
snapshots)
The snapshot delete feature is available through the
RAIDar Manage > Volume Management > Snapshot
Services > Delete Snapshot. Delete any snapshots that
should have been deleted by the delete all
command.
A similar sequence will also work from the CLI.
2158 Luns disappear from host during
failover (12 SATA/12 SAS)
If a disk or LUN becomes disconnected from the
system, use the Disk Management menu and rescan for
the lost disk or LUN.
2229 RedHat Path-Failover: mdadm
path-failover fails 2Gb-Emulex
LP11002 (freeze server)
For RHEL 4 update 3 use the dm_multipath for multi
path configurations.
2331 Cache Hang on shutdown/restart
2394 Product code referencing wrong
FRUID data field
Since a large number of units have already been
shipped with the error in the FRUID's SEEPROM and
attempting to make corrections to the product
application and SMPROD can be extensive, FRUID
will be reprogrammed at System Test with known error.
2567 System crash with error pointing
to MPIO - faulting module
dsmcli.exe
Stopping I/O before interrupting the I/O path between
the host and the storage, reducing the number of LUNs
mapped to the host, or reducing the queue depth limit
in the HBA driver may reduce the probability of this
problem occurring.
2592 Remote Boot: Disk boot succeeds
to Lun0 but I/O fails to other
volumes
Increase the HBA timeout value to 120.
2618 DM-MP: SLES 9.0 SPK3 File
System Corruption on multipath
when controller shutdown
Root cause under investigation.
2644 KILLED OTHER PCIE Msg TO 2
C0000508h 001Ah 0001h
Table 14 Known Bugs
Number Summary Workaround