Seagate ST3250824NS Manuel d'utilisateur Page 26

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 28
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 25
26 R/Evolution Storage System Release Notes December 2006
2721 After disabling a switch port, last
log messages says link up
2761 Both systems showed UFS
problems ("ufs log for ... changed
state to Error")
2833 LS_RJT sent after changing
switch ports; Neptune port is
unavailable
2859 I/O performance Errors
2907 after clear metadata of all 4 disks
caused leftover-state
2926 Solaris Leadville UFS Errors:
FO/FB with I/O through switch
causes UFS errors
Solaris 9: Edit the /kernel/drv/fcp.conf file to have the
following parameter: fcp_offline_delay = 60; Solaris
10: No Solution discovered yet"
2942 FIT: iSCSI External PHY
interface error not detected
2943 FIT: iSCSI External PHY power
failure not detected
2945 FIT: iSCSI External DDR
memory error not detected
2947 FIT: iSCSI External NVRAM
error not detected
3023 Hardware: Single Controller
Cache ECC Uncorrectable Error
(Activity Stop / NMI error)
3037 Code load: EC code load in 200-
level code causes CAPI to hang
3041 Customer Disk channel error:
Protocol Error 0080
3065 JBOD dropped from raid
controller
3078 Controller NMI while heavy load
(HBA pull test)
Table 14 Known Bugs
Number Summary Workaround
Vue de la page 25
1 2 ... 21 22 23 24 25 26 27 28

Commentaires sur ces manuels

Pas de commentaire